UFD is used to indicate the payable toll fare to the road user and when the payment has been made, the publicity message can be shown. The main funcon of User Fare Display is to inform the driver of the vehicle classificaon entered by the toll collector and the toll to be paid. It shall also convey low balance warnings, traffic safety messages, public relaons and seasonal messages.
Toll fare Indicator consist of.
Product Name | Toll fare Indicator |
Make | Eco Track Systems |
Technology | LEDs |
Size | 600 mm x 160 mm |
Colour | Red LED |
Aspects | Red Aspect |
Enclosure | Metal Body, Intensity control by software, |
Interface Communication | RS 232 serial communications |
Voltage | 230V AC |
IP Rating | IP65 |
PCB | Glass epoxy NEMA FR4, Black masking on front and green masking on rear. |
Power Supply | 230 V AC / 50 Hz |
Power consumption | 30watt approx. |
Visibility | > 20 meters under normal condition |
Environmental Protection | Conforming to IP 65 (LED sealed retrofit kit) |
Operating Temperature | -5°C to +65°C |
Weight | 10 kg maximum |
Humidity | 95 % Rh |
LED Reliability | > 100000 Hours |
Communication interface | RS232/RS485, two way communication |
Pixel Pitch | 10mm |
Display Language | English, Hindi and Local Language |
Product Name | Toll fare Indicator |
Make | Eco Track Systems |
Technology | LEDs |
Size | 600 mm x 160 mm |
Colour | Red LED |
Aspects | Red Aspect |
Enclosure | Metal Body, Intensity control by software, |
Voltage | RS 232 serial communications |
PCB | Glass epoxy NEMA FR4, Black masking on front and green masking on rear. |
Power Supply | 230 V AC / 50 Hz |
Power consumption | 30watt approx. |
Visibility | > 20 meters under normal condition |
Wave Length | Red – 630 nm and Green – 526 nm |
LED Intensity | 15000-20000 5mm |
LED Pitch | 10 mm |
Environmental Protection | Conforming to IP 65 (LED sealed retrofit kit) |
Operating Temperature | -5 C to +65 C |
Weight | 6 kg maximum |
Humidity | 95 % Rh |
MTTR | 30 minutes |
LED Reliability | > 100000 Hours |
CE Certification | CE/21N3192 |
ISO 9001:2015 | Certificate Number: 305021081303Q |
IP Protection | IP65 |
Model | ETS-BB 3000 |
Automation Grade | Automatic |
Speed | 0.9 second – 1 second |
Max Boom Arm Length | 3 Meters |
Motor Input Power | 150W |
Input power Supply Voltage | 220 V AC (+- 10%) |
Max Torque | 240 NM with 36 Rotation Min. |
Anti-Crash | Built in. Reverse on hit by vehicle |
Boom Type | Straight or folded |
Boom Weight | Approx. 3 kg |
Boom Dimensions | 46 mm. x 79 mm. |
Motor Speed | 400 rpm |
Base Material | Iron |
Frequency | 50 / 60 Hz |
Rated Power | 100 Watts |
Duty Cycle | 100% |
Working Temp. | -35 to 75 degree cel. |
Relative Humidity | ≤ 90% |
Protection | IP 54 Rated |
Net Weight | 60 kg. |
Remote Working Range | ≥ 30m |
Compatibility | All Type of RFID Readers, IOT Controller, Loop, Photocells (Anti Crash Sensor), Ticket Dispensing Machines etc. |
Accessories | Remote, Push Button, Loop, Photocells |
Counter Balance | 2 tension spring crank transmission design. Electronic Clutch design |
MTBF | 6.5 Million |
Model | ETS-CC 01 | ETS-CC 02 | ETS-CC 04 |
Door Capacity | 1 | 2 | 4 |
Wiegand Interface | 2 | 4 | 4 |
Exit Button Connection | 1 | 2 | 4 |
EM Lock Connection | 1 | 2 | 4 |
Sensor Connection | 1 | 2 | 4 |
Access Log | 60,000 entries | 60,000 entries | 60,000 entries |
Extendable TTL Interface (Require extra component) | 2 (Reserved) | 1 (Reserved) | 1 (Reserved) |
Extendable Input (Require extra component) | 2 (Reserved) | 2 (Reserved) | 2 (Reserved) |
Extendable Output (Optional relay box module) | 4 (Optional) | 4 (Optional) | 4 (Optional) |
Fire Alarm Connection | V | V | V |
Power Box LED Connection | V | V | V |
TCP/IP Interface | V | V | V |
Two Ways Access Control | V | V | X |
Accessibility To Wiegand Reader's Light and Buzzer | V | V | V |
Power Requirement | DC 9-24V | DC 9-24V | DC 9-24V |
Power Consumption (Exclude external device) | 180mA | 220mA | 300mA |
Suggest Power Spec.(Include extra relay box module and Wiegand readers) | 1A | 1.5A | 2A |
EM Lock Relay Box Spec. | 10A 277VAC/28VDC | 10A 277VAC/28VDC | 10A 277VAC/28VDC |
Extend Input Spec. | 0-3.3V | 0~3.3V | 0~3.3V |
Extend Output Spec. | 0-3.3V | 0~3.3V | 0-3.3V |
Wiegand Reader Power Requirement | 9-24V | 9-24V | 9-24V |
Reader Communication Mode | Wiegand 26-66 bit | Wiegand 26-66 bit | Wiegand 26-66 bit |
Max. Range for Wiegand Reader | 80 Meters | 80 Meters | 80 Meters |
Operation Temperature | 0~55°C | 0-55 °C | 0~55°C |
Operation Humidity | 5%~80%,RH | 5%~80%,RH | 5%~80%,RH |
Dimension/Weight | 138x114x27mm/150g | 200x114x27mm/200g |
200x114x27mm/250g |
Model | ETS-BB PRO |
Automation Grade | Automatic |
Speed | 0.5 second – 0.6 second |
Max Boom Arm Length | 3 Meters |
Motor Input Power | 300W |
Input power Supply Voltage | 220 V AC (+- 10%) |
Max Torque | 480 NM with 90 Rotation Min. |
Anti-Crash | Built in. Reverse on hit by vehicle |
Boom Type | Carbon Steel Straight |
Boom Weight | Approx. 3 kg |
Boom Dimensions | 46 mm. x 79 mm. |
Base Material | Iron |
Frequency | 50 / 60 Hz |
Rated Power | 100 Watts |
Duty Cycle | 100% |
Working Temp. | -35 to 75 degree cel. |
Relative Humidity | ≤ 90% |
Protection | IP 54 Rated |
Net Weight | 64 kg. |
Remote Working Range | ≥ 30m |
Compatibility | All Type of RFID Readers, IOT Controller, Loop, Photocells (Anti Crash Sensor), Ticket Dispensing Machines etc. |
Accessories | Remote, Push Button, Loop, Photocells |
Counter Balance | 3 tension spring crank transmission design. Electronic Clutch design |
MTBF | 10.5 million |